PMTZ — Pressuremeter Test Results - Zeros¶
Path: PROJ → LOCA → PMTG → PMTZ · Family: In-Situ Loading, Deformation & Geophysics
Editions: 4.2
New in AGS 4.2
This group was introduced in AGS edition 4.2.
Key chain
Identified by LOCA_ID, PMTG_DPTH, PMTG_TESN, PMTZ_PARM. Inherits LOCA_ID, PMTG_DPTH, PMTG_TESN from PMTG.
| Heading | Status | Type | Unit | Description |
|---|---|---|---|---|
LOCA_ID (key) |
KEY | ID |
Location identifier | |
PMTG_DPTH (key) |
KEY | 2DP |
m | Depth of test |
PMTG_TESN (key) |
KEY | X |
Test reference | |
PMTZ_PARM (key) |
KEY | PA |
Measured Parameter | |
PMTZ_MRS |
OTHER | X |
Measuring ranges of the sensors, min to max unit | |
PMTZ_ZC |
OTHER | U |
Zero from calibration | |
PMTZ_ZB |
OTHER | U |
Zero before at surface | |
PMTZ_ZH |
OTHER | U |
Zero in hole before test at test depth | |
PMTZ_ZA |
OTHER | U |
Zero after at surface | |
PMTZ_ZD |
OTHER | U |
Zero drift | |
PMTZ_EGUT |
OTHER | PU |
Unit for PMTZ_ZD | |
PMTZ_REM |
OTHER | X |
Remarks | |
FILE_FSET |
OTHER | X |
Associated file reference (e.g. equipment calibrations) |