IRES — In Situ Resistivity Tests¶
Path: PROJ → LOCA → IRES · Family: Geoenvironmental & Chemical Testing
Editions: 4.0.3 – 4.2
Key chain
Identified by LOCA_ID, IRES_DPTH, IRES_TESN. Inherits LOCA_ID from LOCA.
| Heading | Status | Type | Unit | Editions | Description |
|---|---|---|---|---|---|
LOCA_ID (key) |
KEY | ID |
Location identifier | ||
IRES_DPTH (key) |
KEY | 2DP |
m | Depth to which in situ resistivity test relates | |
IRES_TESN (key) |
KEY | X |
Test reference | ||
IRES_BASE |
OTHER | 2DP |
m | Base depth to which in-situ resistivity test relates | |
IRES_TYPE |
OTHER | PA |
Type of resistivity test | ||
IRES_DATE |
OTHER | DT |
yyyy-mm-dd | Test date | |
IRES_IRES |
OTHER | 2SF |
ohm m | Mean value of the apparent resistivity | |
IRES_RES1 |
OTHER | 2SF |
ohm m | First value of apparent resistivity when more than 15% different to mean | |
IRES_RES2 |
OTHER | 2SF |
ohm m | Second value of apparent resistivity when more than 15% different to mean | |
IRES_REM |
OTHER | X |
Details of test e.g. electrode spacing and configuration | ||
IRES_ENV |
OTHER | X |
Details of weather and environmental conditions during test | ||
IRES_METH |
OTHER | X |
Test method | ||
IRES_CONT |
OTHER | X |
Name of testing organization | ||
IRES_CRED |
OTHER | X |
Accrediting body and reference number (when appropriate) | ||
TEST_STAT |
OTHER | X |
Test status | ||
GEOL_STAT |
OTHER | X |
Stratum reference shown on trial pit or traverse sketch | ||
FILE_FSET |
OTHER | X |
Associated file reference (e.g. test result sheets) | ||
IRES_OPER |
OTHER | X |
since 4.2 | Name of test operator |