Skip to content

CPTY — Cone Penetration Test (CPT/CPTu) - Cyclic Tests

Path: PROJLOCACPTGCPTY · Family: In-Situ Penetration & Strength Tests

Editions: 4.2

New in AGS 4.2

This group was introduced in AGS edition 4.2.

Key chain

Identified by LOCA_ID, CPTG_TESN, CPTY_TESN. Inherits CPTG_TESN, LOCA_ID from CPTG.

Heading Status Type Unit Description
LOCA_ID (key) KEY ID Location identifier
CPTG_TESN (key) KEY X Test reference or push number
CPTY_TESN (key) KEY X Cyclic test number
CPTY_DPTH OTHER 2DP m Top depth of cyclic test corrected for inclination
CPTY_DINT OTHER 2DP m Depth Interval of cyclic test
CPTY_NUMC OTHER 0DP Number of full cycles in cyclic test
CPTY_REDI OTHER 0DP Initial reading number of cyclic test
CPTY_REDF OTHER 0DP Final reading number of cyclic test
CPTY_TIMI OTHER 1DP s Initial elapsed time (CPTT_TIME) of cyclic test
CPTY_TIMF OTHER 1DP s Final elapsed time (CPTT_TIME) of cyclic test
CPTY_REM OTHER X Remarks, including early termination reason
FILE_FSET OTHER X Associated file reference (e.g. raw field data)