DMTT — Flat Dilatometer Test - Data¶
Path: PROJ → LOCA → DMTG → DMTT · Family: In-Situ Loading, Deformation & Geophysics
Editions: 4.2
New in AGS 4.2
This group was introduced in AGS edition 4.2.
Key chain
Identified by LOCA_ID, DMTG_TESN, DMTT_DPTH. Inherits DMTG_TESN, LOCA_ID from DMTG.
| Heading | Status | Type | Unit | Description |
|---|---|---|---|---|
LOCA_ID (key) |
KEY | ID |
Location identifier | |
DMTG_TESN (key) |
KEY | X |
Test reference | |
DMTT_DPTH (key) |
KEY | 2DP |
m | Depth of result |
DMTT_MTH |
OTHER | 0DP |
kg | Thrust |
DMTT_BCVA |
OTHER | 2DP |
kPa | Blade calibration value for specific depth record, delta A |
DMTT_BCVB |
OTHER | 2DP |
kPa | Blade calibration value for specific depth record, delta B |
DMTT_TMST |
OTHER | DT |
yyyy-mm-ddThh:mm:ss | Pressurisation start time |
DMTT_A |
OTHER | 2DP |
kPa | A-pressure test reading |
DMTT_TMA |
OTHER | 1DP |
s | A-position time since start of pressurisation |
DMTT_B |
OTHER | 2DP |
kPa | B-pressure test reading |
DMTT_TMB |
OTHER | 1DP |
s | B-position time since start of pressurisation |
DMTT_C |
OTHER | 2DP |
kPa | C-pressure test reading |
DMTT_TMC |
OTHER | 1DP |
s | C-position time since start of pressurisation |
DMTT_P0 |
OTHER | 0DP |
kPa | Corrected test reading A, p_0 |
DMTT_P1 |
OTHER | 0DP |
kPa | Corrected test reading B, p_1 |
DMTT_P2 |
OTHER | 0DP |
kPa | Corrected test reading C, p_2 |
DMTT_INCX |
OTHER | 1DP |
deg | Inclination 1 (the axis through the membrane) |
DMTT_INCY |
OTHER | 1DP |
deg | Inclination 2 (the axis across the width of the blade) |
DMTT_RATE |
OTHER | 0DP |
mm/s | Penetration rate |
DMTT_REM |
OTHER | X |
Remarks on specific depth readings | |
FILE_FSET |
OTHER | X |
Associated file reference |
Child groups (1)¶
DMTP— Flat Dilatometer Test - Derived Parameters