Skip to content

CPDT — Pore Pressure Dissipation Tests (PPDT) - Data

Path: PROJLOCACPTGCPDGCPDT · Family: In-Situ Penetration & Strength Tests

Editions: 4.2

New in AGS 4.2

This group was introduced in AGS edition 4.2.

Key chain

Identified by LOCA_ID, CPTG_TESN, CPDG_DPTH, CPDT_TIME. Inherits CPDG_DPTH, CPTG_TESN, LOCA_ID from CPDG.

Heading Status Type Unit Description
LOCA_ID (key) KEY ID Location identifier
CPTG_TESN (key) KEY X Test reference or push number
CPDG_DPTH (key) KEY 2DP m Inclination corrected depth of dissipation test
CPDT_TIME (key) KEY 1DP s Elapsed time since start of test
CPDT_QC OTHER 3DP MPa Cone resistance (q_c)
CPDT_TF OTHER 3DP kN Total force or thrust
CPDT_FS OTHER 4DP MPa Sleeve friction (f_s)
CPDT_U1 OTHER 4DP MPa Face porewater pressure (u_1)
CPDT_U2 OTHER 4DP MPa Shoulder porewater pressure (u_2)
CPDT_U3 OTHER 4DP MPa Top of sleeve porewater pressure (u_3)
CPDT_TMPI OTHER 1DP DegC Cone internal temperature. If multiple temperature sensors exist, then the sensor closest to the pore pressure sensors should be used.
CPDT_REM OTHER X Comments
FILE_FSET OTHER X Associated file reference (e.g. test result sheets)