LTCH — Laboratory Thermal Conductivity¶
Path: PROJ → LOCA → SAMP → LTCH · Family: Soil Classification & Index Tests
Editions: 4.1 – 4.2
New in AGS 4.1
This group was introduced in AGS edition 4.1.
Key chain
Identified by LOCA_ID, SAMP_TOP, SAMP_REF, SAMP_TYPE, SAMP_ID, SPEC_REF, SPEC_DPTH. Inherits LOCA_ID, SAMP_ID, SAMP_REF, SAMP_TOP, SAMP_TYPE from SAMP.
| Heading | Status | Type | Unit | Description |
|---|---|---|---|---|
LOCA_ID (key) |
KEY | ID |
Location identifier | |
SAMP_TOP (key) |
KEY | 2DP |
m | Depth to top of sample |
SAMP_REF (key) |
KEY | X |
Sample reference | |
SAMP_TYPE (key) |
KEY | PA |
Sample type | |
SAMP_ID (key) |
KEY | ID |
Sample unique identifier | |
SPEC_REF (key) |
KEY | X |
Specimen reference | |
SPEC_DPTH (key) |
KEY | 2DP |
m | Depth to top of test specimen |
SPEC_DESC |
OTHER | X |
Specimen description | |
SPEC_PREP |
OTHER | X |
Details of specimen preparation including time between preparation and testing | |
SPEC_BASE |
OTHER | 2DP |
m | Depth to base of specimen |
LTCH_COND |
OTHER | X |
Sample condition | |
LTCH_BDEN |
OTHER | 2DP |
Mg/m3 | Bulk density |
LTCH_DDEN |
OTHER | 2DP |
Mg/m3 | Dry density |
LTCH_MC |
OTHER | X |
% | Water/moisture content |
LTCH_TCON |
OTHER | 2DP |
W/(K-m) | Thermal Conductivity |
LTCH_TRES |
OTHER | 2DP |
(K-m)/W | Thermal Resistivity |
LTCH_TEMP |
OTHER | 0DP |
DegC | Ambient temperature at which test is performed |
LTCH_PDIA |
OTHER | 0DP |
mm | Probe diameter |
LTCH_PSPA |
OTHER | 0DP |
mm | Probe spacing |
LTCH_PPEN |
OTHER | 0DP |
mm | Probe penetration |
LTCH_PRBE |
OTHER | X |
Method of probe insertion | |
LTCH_PART |
OTHER | X |
Particle grain size removed | |
LTCH_DEV |
OTHER | X |
Deviation from the procedure | |
LTCH_REM |
OTHER | X |
Remarks | |
LTCH_METH |
OTHER | X |
Test method | |
LTCH_LAB |
OTHER | X |
Name of testing laboratory/organization | |
LTCH_CRED |
OTHER | X |
Accrediting body and reference number (when appropriate) | |
TEST_STAT |
OTHER | X |
Test status | |
FILE_FSET |
OTHER | X |
Associated file reference (e.g. equipment calibrations) |