Skip to content

MONG — Monitoring Installations and Instruments

Path: PROJLOCAMONG · Family: Groundwater & Monitoring

Editions: 4.0.3 – 4.2

Key chain

Identified by LOCA_ID, MONG_ID, MONG_DIS. Inherits LOCA_ID from LOCA.

Heading Status Type Unit Description
LOCA_ID (key) KEY ID Location identifier
MONG_ID (key) KEY X Monitoring point reference
MONG_DIS (key) KEY 2DP m Initial distance of monitoring point from LOCA_ID
PIPE_REF OTHER X Pipe reference
MONG_DATE OTHER DT yyyy-mm-dd Installation date
MONG_TYPE OTHER PA Instrument type
MONG_DETL OTHER X Details of instrument
MONG_TRZ OTHER 2DP m Distance to start of response zone from LOCA_ID datum
MONG_BRZ OTHER 2DP m Distance to end of response zone from LOCA_ID datum
MONG_BRGA OTHER 0DP deg Bearing of monitoring axis A (compass bearing)
MONG_BRGB OTHER 0DP deg Bearing of monitoring axis B (compass bearing)
MONG_BRGC OTHER 0DP deg Bearing of monitoring axis C (compass bearing)
MONG_INCA OTHER 0DP deg Inclination of instrument axis A (measured positively down from horizontal)
MONG_INCB OTHER 0DP deg Inclination of instrument axis B (measured positively down from horizontal)
MONG_INCC OTHER 0DP deg Inclination of instrument axis C (measured positively down from horizontal)
MONG_RSCA OTHER X Reading sign convention in direction A
MONG_RSCB OTHER X Reading sign convention in direction B
MONG_RSCC OTHER X Reading sign convention in direction C
MONG_REM OTHER X Remarks
MONG_CONT OTHER X Contractor who installed monitoring instrument
FILE_FSET OTHER X Associated file reference (e.g. equipment calibrations)

Child groups (2)

  • MOND — Monitoring Readings
  • MONS — Monitoring Installations and Instruments Status