IPRG — In Situ Permeability Tests - General¶
Path: PROJ → LOCA → IPRG · Family: Groundwater & Monitoring
Editions: 4.0.3 – 4.1.1
Removed in AGS 4.2
This group was defined up to AGS 4.1.1 and removed in 4.2.
Key chain
Identified by LOCA_ID, IPRG_TOP, IPRG_TESN, IPRG_BASE, IPRG_STG. Inherits LOCA_ID from LOCA.
| Heading | Status | Type | Unit | Description |
|---|---|---|---|---|
LOCA_ID (key) |
KEY | ID |
Location identifier | |
IPRG_TOP (key) |
KEY | 2DP |
m | Depth to top of test zone |
IPRG_TESN (key) |
KEY | X |
Test reference | |
IPRG_BASE (key) |
KEY | 2DP |
m | Depth to base of test zone |
IPRG_STG (key) |
KEY | 0DP |
Stage number of multistage test | |
IPRG_TYPE |
OTHER | PA |
Type of test | |
IPRG_PRWL |
OTHER | 2DP |
m | Depth to water in test zone immediately prior to test |
IPRG_SWAL |
OTHER | 2DP |
m | Depth to water at start of test |
IPRG_TDIA |
OTHER | 2DP |
m | Diameter of test zone |
IPRG_SDIA |
OTHER | 3DP |
m | Diameter of test installation (e.g. standpipe or casing) |
IPRG_IPRM |
OTHER | 1SCI |
m/s | Permeability |
IPRG_FLOW |
OTHER | 1DP |
l/s | Average flow during test stage |
IPRG_AWL |
OTHER | 2DP |
m | Depth to assumed standing water level |
IPRG_HEAD |
OTHER | 2DP |
m | Applied total head of water during test stage at centre of test zone |
IPRG_DATE |
OTHER | DT |
yyyy-mm-dd | Test date |
IPRG_REM |
OTHER | X |
Test remarks | |
IPRG_ENV |
OTHER | X |
Details of weather and environmental conditions during test | |
IPRG_METH |
OTHER | X |
Test method | |
IPRG_CONT |
OTHER | X |
Name of testing organization | |
IPRG_CRED |
OTHER | X |
Accrediting body and reference number (when appropriate) | |
TEST_STAT |
OTHER | X |
Test status | |
FILE_FSET |
OTHER | X |
Associated file reference (e.g. equipment calibrations) |
Child groups (1)¶
IPRT— In Situ Permeability Tests - Data