IPID — On Site Volatile Headspace Testing by Photo Ionisation Detector¶
Path: PROJ → LOCA → IPID · Family: Geoenvironmental & Chemical Testing
Editions: 4.0.3 – 4.2
Key chain
Identified by LOCA_ID, IPID_DPTH, IPID_TESN. Inherits LOCA_ID from LOCA.
| Heading | Status | Type | Unit | Editions | Description |
|---|---|---|---|---|---|
LOCA_ID (key) |
KEY | ID |
Location identifier | ||
IPID_DPTH (key) |
KEY | 2DP |
m | Depth of headspace test sample | |
IPID_TESN (key) |
KEY | X |
Test reference | ||
IPID_DATE |
OTHER | DT |
yyyy-mm-dd | Test date | |
IPID_TEMP |
OTHER | 1DP |
DegC | Ambient temperature at time of test | |
IPID_RES |
OTHER | XN |
ppmv | Result of PID analysis | |
IPID_REM |
OTHER | X |
Remarks on test | ||
IPID_ENV |
OTHER | X |
Details of weather and environmental conditions during test | ||
IPID_METH |
OTHER | X |
Details of PID used and method description | ||
IPID_CONT |
OTHER | X |
Name of testing organization | ||
IPID_CRED |
OTHER | X |
Accrediting body and reference number (when appropriate) | ||
TEST_STAT |
OTHER | X |
Test status | ||
GEOL_STAT |
OTHER | X |
Stratum reference shown on trial pit or traverse sketch | ||
FILE_FSET |
OTHER | X |
Associated file reference (e.g. test result sheets) | ||
IPID_OPER |
OTHER | X |
since 4.2 | Name of test operator |