LLPL — Liquid and Plastic Limit Tests¶
Path: PROJ → LOCA → SAMP → LLPL · Family: Soil Classification & Index Tests
Editions: 4.0.3 – 4.2
Key chain
Identified by LOCA_ID, SAMP_TOP, SAMP_REF, SAMP_TYPE, SAMP_ID, SPEC_REF, SPEC_DPTH. Inherits LOCA_ID, SAMP_ID, SAMP_REF, SAMP_TOP, SAMP_TYPE from SAMP.
| Heading | Status | Type | Unit | Editions | Description |
|---|---|---|---|---|---|
LOCA_ID (key) |
KEY | ID |
Location identifier | ||
SAMP_TOP (key) |
KEY | 2DP |
m | Depth to top of sample | |
SAMP_REF (key) |
KEY | X |
Sample reference | ||
SAMP_TYPE (key) |
KEY | PA |
Sample type | ||
SAMP_ID (key) |
KEY | ID |
Sample unique identifier | ||
SPEC_REF (key) |
KEY | X |
Specimen reference | ||
SPEC_DPTH (key) |
KEY | 2DP |
m | Depth to top of test specimen | |
SPEC_DESC |
OTHER | X |
Specimen description | ||
SPEC_PREP |
OTHER | X |
Details of specimen preparation including time between preparation and testing | ||
LLPL_LL |
OTHER | 0DP |
% | Liquid limit | |
LLPL_PL |
OTHER | XN |
% | Plastic limit | |
LLPL_PI |
OTHER | 0DP |
Plasticity Index | ||
LLPL_425 |
OTHER | 0DP |
% | Percentage passing 0.425mm sieve | |
LLPL_PREP |
OTHER | X |
Method of preparation | ||
LLPL_STAB |
OTHER | 2SF |
% | Amount of stabiliser added | |
LLPL_STYP |
OTHER | X |
Type of stabiliser added | ||
LLPL_REM |
OTHER | X |
Remarks | ||
LLPL_METH |
OTHER | X |
Test method | ||
LLPL_LAB |
OTHER | X |
Name of testing laboratory/organization | ||
LLPL_CRED |
OTHER | X |
Accrediting body and reference number (when appropriate) | ||
TEST_STAT |
OTHER | X |
Test status | ||
FILE_FSET |
OTHER | X |
Associated file reference (e.g. test result sheets) | ||
SPEC_BASE |
OTHER | 2DP |
m | since 4.1 | Depth to base of specimen |
LLPL_DEV |
OTHER | X |
since 4.1 | Deviation from the specified procedure | |
LLPL_TYPE |
OTHER | PA |
since 4.1 | Type of test | |
LLPL_POIN |
OTHER | PA |
since 4.1 | Number of points | |
LLPL_CONE |
OTHER | PA |
since 4.1 | For fall cone method, type of cone | |
LLPL_1PRE |
OTHER | 1DP |
mm | since 4.1 | Mean of test readings, if one-point test. |
LLPL_1PCF |
OTHER | 3DP |
since 4.1 | Correlation factor if one-point test. | |
LLPL_SIZE |
OTHER | U |
mm | since 4.1 | Sieve size if other than 0.425mm |
LLPL_PASS |
OTHER | 2SF |
% | since 4.1 | Percentage passing LLPL_SIZE sieve if other than 0.425mm |
LLPL_WC |