CPTZ — Cone Penetration Test (CPT/CPTu) - Zeros¶
Path: PROJ → LOCA → CPTG → CPTZ · Family: In-Situ Penetration & Strength Tests
Editions: 4.2
New in AGS 4.2
This group was introduced in AGS edition 4.2.
Key chain
Identified by LOCA_ID, CPTG_TESN, CPTZ_PARM. Inherits CPTG_TESN, LOCA_ID from CPTG.
| Heading | Status | Type | Unit | Description |
|---|---|---|---|---|
LOCA_ID (key) |
KEY | ID |
Location identifier | |
CPTG_TESN (key) |
KEY | X |
Test reference or push number | |
CPTZ_PARM (key) |
KEY | PA |
Measured Parameter | |
CPTZ_ZBD |
OTHER | U |
Zero before at deck/surface (for over water testing where CPTG_RLOC is BB or SB) | |
CPTZ_ZB |
OTHER | U |
Zero before at reference/test level | |
CPTZ_ZA |
OTHER | U |
Zero after at reference/test level | |
CPTZ_ZAD |
OTHER | U |
Zero after at deck/surface (for over water testing where CPTG_RLOC is BB or SB) | |
CPTZ_ZAC |
OTHER | U |
Zero after test when cone has been cleaned at test level/deck/surface | |
CPTZ_ZD |
OTHER | 4DP |
Zero drift between reference readings, CPTZ_ZA - CPTZ_ZB | |
CPTZ_ZDD |
OTHER | 4DP |
Zero drift between deck/surface readings, CPTZ_ZAD - CPTZ_ZBD | |
CPTZ_ZDC |
OTHER | 4DP |
Zero drift between before and cleaned, CPTZ_ZAC - first of CPTZ_ZBD or CPTZ_ZB | |
CPTZ_CD |
OTHER | 4DP |
Calibration drift between calibration or first test, and first of CPTZ_ZBD or CPTZ_ZB | |
CPTZ_ZS |
OTHER | 4DP |
Zero output stability, the difference between maximum and minimum values recorded for one minute | |
CPTZ_ZSS |
OTHER | X |
Origin of zero output stability | |
CPTZ_ZVUC |
OTHER | U |
Zero value used in calculation | |
CPTZ_EGUT |
OTHER | PU |
Engineering unit for CPTZ_ZBD, CPTZ_ZB, CPTZ_ZA, CPTZ_ZAD, CPTZ_ZAC, CPTG_ZD, CPTG_CD and CPTG_ZS | |
CPTZ_REM |
OTHER | X |
Remarks | |
FILE_FSET |
OTHER | X |
Associated file reference |