DMTG — Flat Dilatometer Test - General¶
Path: PROJ → LOCA → DMTG · Family: In-Situ Loading, Deformation & Geophysics
Editions: 4.2
New in AGS 4.2
This group was introduced in AGS edition 4.2.
Key chain
Identified by LOCA_ID, DMTG_TESN. Inherits LOCA_ID from LOCA.
| Heading | Status | Type | Unit | Description |
|---|---|---|---|---|
LOCA_ID (key) |
KEY | ID |
Location identifier | |
DMTG_TESN (key) |
KEY | X |
Test reference | |
DMTG_DATE |
OTHER | DT |
yyyy-mm-ddThh:mm:ss | Test date and time |
DMTG_ORNT |
OTHER | 0DP |
deg | Angle that the membrane is pointing to |
DMTG_PED |
OTHER | 2DP |
m | Pre-drilled depth |
DMTG_WAT |
OTHER | 2DP |
m | Depth to groundwater level, z_w at time of test |
DMTG_WATA |
OTHER | X |
Origin of groundwater level in DMTG_WAT | |
DMTG_TYPE |
OTHER | PA |
Specific details on type of DMT equipment | |
DMTG_REFB |
OTHER | X |
Serial number of blade (if applicable) | |
DMTG_REFA |
OTHER | X |
Serial number of the acquisition unit (if applicable) | |
DMTG_MAN |
OTHER | X |
Manufacturer of the dilatometer | |
DMTG_RIG |
OTHER | X |
Type of penetration rig | |
DMTG_EQPT |
OTHER | X |
Mass, reaction and equipment geometry | |
DMTG_COT |
OTHER | X |
Method and calibration of thrust measurement | |
DMTG_TDR |
OTHER | X |
Type and diameter of penetration rods | |
DMTG_DIMS |
OTHER | X |
Geometry and dimensions of the dilatometer, as measured | |
DMTG_PRSG |
OTHER | X |
Measuring range of the pressure gauges and zero offset when vented | |
DMTG_FRIC |
OTHER | X |
Details of any rod friction reducer, including diameter | |
DMTG_DITH |
OTHER | 2DP |
mm | Membrane thickness |
DMTG_BCVA |
OTHER | 2DP |
kPa | Blade calibration value used, delta A |
DMTG_BCVB |
OTHER | 2DP |
kPa | Blade calibration value used, delta B |
DMTG_FAED |
OTHER | 1DP |
MPa | Dilatometer modulus (Ed) factor |
DMTG_FAS0 |
OTHER | 1DP |
mm | Membrane displacement |
DMTG_TERM |
OTHER | X |
Termination reason(s) | |
DMTG_CORR |
OTHER | X |
Corrections applied during data processing (e.g. depth corrections, zeros) | |
DMTG_REM |
OTHER | X |
Note on set up conditions, comments on testing, types of materials encountered if possible | |
DMTG_OPER |
OTHER | X |
Name of test operator | |
DMTG_ANBY |
OTHER | X |
Name(s) of analyser / person responsible for data quality and correctness | |
DMTG_ENV |
OTHER | X |
Details of weather and environmental conditions during test | |
DMTG_METH |
OTHER | X |
Standard followed for testing | |
DMTG_DEV |
OTHER | X |
Deviations from the standard followed | |
DMTG_CONT |
OTHER | X |
Subcontractors name | |
DMTG_CRED |
OTHER | X |
Accrediting body and reference number (when appropriate) | |
TEST_STAT |
OTHER | X |
Test status | |
FILE_FSET |
OTHER | X |
Associated file reference |