Skip to content

PMMD — Menard Pressuremeter Test Results - Data

Path: PROJLOCAPMMGPMMD · Family: In-Situ Loading, Deformation & Geophysics

Editions: 4.2

New in AGS 4.2

This group was introduced in AGS edition 4.2.

Key chain

Identified by LOCA_ID, PMMG_DPTH, PMMG_TESN, PMMD_SEQ. Inherits LOCA_ID, PMMG_DPTH, PMMG_TESN from PMMG.

Heading Status Type Unit Description
LOCA_ID (key) KEY ID Location identifier
PMMG_DPTH (key) KEY 2DP m Depth of test
PMMG_TESN (key) KEY X Test reference
PMMD_SEQ (key) KEY 0DP Sequence number
PMMD_P01S OTHER 3DP MPa Measured pressure at 1 s
PMMD_P15S OTHER 3DP MPa Measured pressure at 15 s
PMMD_P30S OTHER 3DP MPa Measured pressure at 30 s
PMMD_P60S OTHER 3DP MPa Measured pressure at 60 s
PMMD_V01S OTHER 1DP cm3 Measured volume at 1 s
PMMD_V15S OTHER 1DP cm3 Measured volume at 15 s
PMMD_V30S OTHER 1DP cm3 Measured volume at 30 s
PMMD_V60S OTHER 1DP cm3 Measured volume at 60 s
PMMD_CP OTHER 3DP MPa Corrected pressure
PMMD_CVOL OTHER 1DP cm3 Corrected volume
PMMD_SLOP OTHER 0DP cm3/MPa Slope
PMMD_CREP OTHER 1DP cm3 Creep
PMMD_REM OTHER X Remarks
FILE_FSET OTHER X Associated file reference (e.g. test result sheets)